| Structure | Unit | Parameter | |
| Fiber count | Fibers | 2 | |
| Diameter | mm | 5.0*2.0 | |
| Weight | Kg/km | Approx.21 | |
| Case color |
| Black | |
| Cover material |
| LSZH | |
| OF steel wire | mm | 1.0±0.05mm | |
| Force member | mm | 0.5mm FRP | |
| Tension Force | N | 1500 | |
| Crush resistance | N | 2200 | |
| Warp Radio | Dynamic |
| 30 |
| Static |
| 15 | |
| Operating temperature | ℃ | -40 --- +70 | |
| Category | Description
| Specs | |
| G.657A1 | |||
| Optical specifications | Attenuation | @1310-1625nm | ≤0.36dB/km |
| @1383±3nm | ≤0.36dB/km | ||
| @1550nm | ≤0.22dB/km | ||
| Attenuation discontinuity | ≤0.05 dB | ||
| Attenuation versus wavelength | @1285~1330nm | ≤0.05 dB/km | |
| @1525~1575nm | ≤0.05 dB/km | ||
| Zero dispersion wavelength | 1300~1324nm | ||
| Zero dispersion slope | ≤0.092ps/(nm2.km) | ||
| Dispersion | @1310nm | ≤3.5 ps/nm.km | |
| @1550nm | ≤18 ps/nm.km | ||
| Polarization mode dispersion (PMD) | ≤0.2ps/km1/2 | ||
| Cable cutoff wavelength (λcc) | ≤1260nm | ||
| Effective group refractive index | @1310nm | 1.4675 | |
| @1550nm | 1.4681 | ||
| Pérdida de macro curva (30mm radius ,100turns) 1625nm | ≤0.1 dB | ||
| Geometric Specs | Mode Field Diameter | @1310nm | 9.2±0.6μm |
| @1550nm | 10.4±0.8μm | ||
| Lining diameter | 125±1μm | ||
| Non-circular coating | ≤1.0% | ||
| Lining diameter | 245±7μm | ||
| Coating/liningConcentricity error | ≤8μm | ||
| Core/claddingConcentricity error | ≤0.8μm | ||
| Mechanics Specs | Test level | ≥1.0% | |
| Fiber bending radius | ≥4.0m | ||
| Maximum strength of the coating strip | 1.3~8.9N | ||
The drop cable is designed for the last mile in the FTTx network, improving fiber accessibility and maximizing the functionality of the installation.
1. Two parallel steel wire/FRP strength members ensure good crush resistance performance to protect the fiber.
2. Simple structure, light weight and high practicality;
3. Peel and splice easily, simplifying installation and maintenance;
4. Low smoke emission, zero halogens and fireproof cover.
1. It is used in the access network or as an outdoor-to-indoor access cable in the customer premises network;
2. Used as a building access cable in the premises distribution system, especially used indoors or outdoors.





Mr. Herry
Phone/Wechat/Whatsapp:+8618123897029
Skype: sales09@aixton.com
Mr James
Phone/Wechat/Whatsapp:+8618566291592
Skype:aixton05